Non-Plenum Fire Alarm Cable 12AWG 2 Cores Solid Copper Shielded UL FPL Standard

Categories Fire Alarm Cable
Place of Origin: China
Brand Name: KINGTONE OR OEM
Certification: ISO, CE, RoHS, UL
Model Number: FPL 12 AWG Fire Alarm Cable
MOQ: 20 KM
Packaging Details: 500FT, 1000FT, Pull Box, Pallet
Delivery Time: 25 working days
Payment Terms: T/T, L/C
Supply Ability: 1000KM / Month
Conductor: Bare Copper
Insulation: FPL-PVC
Shield: PET / AL-Foil
Jacket: FPL-PVC
Color: Red
Package: 500FT, 1000FT, Pull Box, Pallet
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile
    English
    Français
    Русский язык
    Español
    日本語
    Português

    Non-Plenum Fire Alarm Cable 12AWG 2 Cores Solid Copper Shielded UL FPL Standard


    Non-Plenum Fire Alarm Cable 12AWG 2 Cores Solid Copper Shielded UL FPL Standard


    Quick Details


    • Fire Alarm Cable
    • FPL 12AWG 2 Cores
    • Solid Copper Conductor
    • Unshielded Types: 2C
    • Shielded Types: 2C
    • Non-Plenum PVC Jacket
    • 500FT, 1000FT, Plastic Spool, Carton
    • Fire Power Limited Cable

    Description


    KINGTONE ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760.
    NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled and powered by the fire alarm system.
    These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered
    and controlled by the fire alarm system."
    Type FPL- FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose
    fire alarm use.This listing excludes installation in riser, ducts, plenums and other spaceused for
    environmental air unless the cable is installed in conduit.All FPL cables are listed as being resistant to
    the spread of fire and must pass both UL test 1424 and the vertical flame testUL 1581.
    KT1420 Fire Alarm Cables 12 AWG FPL-CL2 PVC Insulation Non-Plenum PVC Jakcet
    Application
    Indoor for:
    Audio Circuits
    Control Circuits
    Initiating Circuits
    Notification Circuits
    Properties
    Temperature Rating: '-20 to 75℃
    Operating Voltage: 300 Volts max.
    Flame Rating: UL 1685 Vertical Tray
    Insulation & Jacket: PVC
    Unshielded types
    ConductorsNOM.THICKNESS(MM)Nominal0.D.CapacitanceImpedanceDC Resistance
    NumberSolidInsulationJacketInchpf/ftOhmsOhms/M'
    212 AWG0.012"0.016"0.242"22701.6
    Shielded types
    ConductorsNOM.THICKNESS(MM)Nominal0.D.CapacitanceImpedanceDC Resistance
    NumberSolidInsulationJacketInchpf/ftOhmsOhms/M'
    212 AWG0.010"0.017"0.240"56301.6
    Drain Wire16 AWG Solid Tinned-Copper
    Shield0.001" thick Aluminum/Mylar
    Color
    NumberDescription
    2Blk,Red
    Order Informations:
    Print

    KINGTONE KT1420 ×C12 E×××××××(UL)

    FPL OR CL2 SUN RES(ROHS) ××××FT
    DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

    Packing500FT, 1000FT, Pull Box, Pallet

    Competitive Advantage:


    1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

    A, Incoming material inspected by QC.

    B, Manufacturing Process Control

    C: Workers trained daily/weekly/monthly

    D: Work instructions manual at each work station

    E: 5S system implemented

    F: Machine maintenance procedure

    G: Quality Control and Final Inspection

    The QC staff will check the material, process product

    and final product according to the specification or test procedure.

    2, Our R&D efforts center on reinforcing and developing element technologies

    needed to support the future growth and success for customers and KINGTONE.

    3, We know customers have urgent needs.

    We are skilled at effective communication to interact with customers.

    In order to provide prompt service, we can answer for you 7*24 hours.

    4, We can Quickly and professionally answer for the inquire

    5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

    6, Intime delivery


    Quality Non-Plenum Fire Alarm Cable 12AWG  2 Cores Solid Copper Shielded UL FPL Standard for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: KINGTONE ELECTRONICS CO.,LTD (1)
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0