Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h

Categories Nitrogen Generation Plant
Brand Name: Hangyang
Model Number: KDN
Certification: CE/ASEM/GB
Place of Origin: China
MOQ: 1 set
Price: according to actual requirement
Payment Terms: negotiation
Supply Ability: according to actual requirement
Delivery Time: according to actual requirement
Packaging Details: wooden case, nude packing, container
Product Name: Nitrogen generation plant 4800 Nm3/h / 40 Nm3/h KDN-4800/40Y
Application: Glass,Oil and Gas Field,Machinery & Construction,Metallurgy
Output(Nm3/h): 4500~5000
Standard: CE/ASEM/GB
Pressure: 0.01/0.15
Service: Engineers available to commissioning service overseas
Delivery Term: FOB Shanghai
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile
    English
    Français
    Русский язык
    Español
    日本語
    Português

    Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h


    Nitrogen generation plant 4800 Nm3/h / 40 Nm3/h KDN-4800/40Y


    Specifications:


    The Standard Products for the Nitrogen Generator KDN 4500~ 5000 Series


    MODEL

    CONTENTS

    KDN-4500/200Y

    KDN-4800/200Y

    KDN-4200/420Y

    KDN-4820/300Y

    GAN/LIN flow

    Nm3/h

    4500/200

    4800/200

    4800/420

    4820/300

    GAN/LIN purity

    ppm

    10ppm(O2)

    10ppm(O2)

    1ppm(O2)

    5ppm(O2)

    GAN/LIN pressure

    MPa

    0.7

    0.7

    0.7

    0.67

    Subcooled

    13/-172

    13/-173

    13/-173

    13/-174


    Typical Product: KDN-4800/40Y Nitrogen generation plant


    Output, purity and pressure



    Flow (Nm3/h)

    Purity

    Pressure MPa(G)

    Subcooled (℃)

    GAN/LN

    4800 Nm3/h / 40 Nm3/h

    ≤3ppm(O2)

    0.01/0.15

    14/-192


    Description:


    First step: air goes through filter to remove dust and mechanical impurities

    Second step: air goes into compressor to be compressed

    Third step: air goes into pre-cooling unit to be cooled to 5~8℃ and to saturated condition

    Forth step: air goes into molecular sieve (such as MS1) to adsorb hydrocarbon like H2O, CO2, C2H2

    Fifth step: air is divided into three steams: one steam as instrument air, the second steam flows into the main heat exchanger E1 directly to be cooled, and then part of it will reach saturation temperature after going out of E1, and then goes to the bottom of lower column C1 to follow the rectification; the third steam goes to the main heat exchanger after being boosted and cooled in the boosting end of expander, and then it is withdrawn from the middle of heat exchanger to the expander for expansion refrigeration, and part expanded air will be fed to the upper column to follow the rectification, and the rest goes out of cold box after it backflows to the main heat exchanger and be rewarmed.

    Sixth step: air is separated into pure liquid nitrogen and liquid air after being rectified in the lower column. The liquid air in the bottom of lower column goes into the lower part of upper column through sub-cooling throttling, and then flows into the condensation evaporator as the cold source of condensation rising nitrogen by the column plate.

    For the liquid nitrogen in the top of lower column, part of it will be drawn out and go to the top of upper column to follow the rectification, and the rest will be extracted as product.

     The oxygen enriched gas in the bottom of upper column is drawn out and goes into the sub-cooler and main heat exchanger to be re-warmed, and then goes out of cold box to be as the regeneration gas of molecular sieve adsorber.

     The nitrogen in the top of upper column will be withdrawn as the product, and goes out of cold box after being re-warmed in the sub-cooler and main heat exchanger, and then fed to the piping net after being boosted to the pressure required by the user.

     In order to make sure the safe running of plant, a small part liquid in the condensation evaporator should be discharged out of column regularly to avoid the accumulation of hydrocarbon, especially acetylene.



    Applications:

    1. Modified Atmosphere Gas
    2. Inert Gas
    3. Nitrogen Purging & Pressurize Test
    4. Agriculture
    5. Pharmaceutical and biotechnology
    6. Petroleum and natural gas

    Competitive Advantage:

    1. Very simple and safe to operate
    2. Low Maintenance Cost
    3. Short time delivery. Good service.
    4. Successful experience of made many plants
    5. No loss, high returns