Sign In | Join Free | My atjoomla.com
atjoomla.com
Products
Search by Category
Home > Air-Compressors >

IP65 Outdoor Telecom Cabinet

Categories Outdoor Telecom Cabinet
Brand Name: ESTEL
Model Number: ET100100180B
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin: Shenzhen, China (Mainland)
MOQ: 1 set
Price: negotiation
Payment Terms: L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability: 7,200 sets per month
Delivery Time: 15-20 working days
Packaging Details: wooden case
Cable Entry: from cabinet bottom
Material: galvanized steel
Cabinet Lock: anti-theft three point lock
External Dimension: H×W×D 1800×1000×1000mm
Doors: two
Illumination: DC48V LED lamp
Cooling: DC48V 500W air conditioner
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile
    English
    Français
    Русский язык
    Español
    日本語
    Português

    IP65 Outdoor Telecom Cabinet


    IP65 19” Outdoor Telecom Equipment Cabinet With DC48V Cooling System / Customized Metal Outdoor Telecom Cabinet


    Quick Details


    Place of Origin: Shenzhen, China (Mainland)External Size H×W×D 1800×1000×1000mm

    Brand Name: ESTEL

    Structure: double wall, with insulation, sandwich structure

    Model Number: ET100100180B

    Cabinet Layout: one compartment, for installing 19” equipment

    Product Name: Outdoor Telecom Equipment Cabinet

    Cabinet Lock: anti-theft three point lock
    Certification: ISO9001, CE, 3C, FCC, TLC, IP55

    Protection Level: IP65

    Application: outdoor telecom base stationCable Entry: at cabinet bottom
    Material: galvanized steelIllumination: DC48V LED lamp

    Heat Insulation: PEF

    Grounding Protection: copper bar

    Color: grey (support custom made)

    Cooling: DC48V 500W air conditioner

    Coating: anti-corrosion outdoor powder coating

    Accessories Options: PDU,environment monitoring system

    Payment & Shipping Terms


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
    Supply Ability:7,200 sets per month
    Delivery Time:15-20 working days
    Packaging Details:wooden case


    1. Specifications


    (1) Technical Parameters


    ItemTypeTechnical Parameter
    StructureDimensionExternal Dimension H×W×D 1800×1000×1000mm
    LayoutOne compartment
    Equipment Installation Method19” standard rack
    Door

    With one front door and one back door, totally two doors;

    with anti-theft three point lock for outdoor cabinet (support padlock)

    Material

    1.Galvanized steel;

    2.double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

    StructureAssembled
    Ingress ProtectionIP65
    Temperature ControlCooling

    DC48V 500W air conditioner

    LightingLED lamp48V LED lamp
    TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
    Storage Temperature: -50°C ~ + 70°C
    Transport Temperature: -50°C ~ +70°C
    HumidityRelative Humidity5% ~99%
    PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
    Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

    (2) Accessories List


    No.ItemQuantityUnitSpecs
    1Outdoor Telecom Cabinet1Set

    (1) External Size H×W×D 1800×1000×1000mm

    (2) One compartment;

    (3) With one front door and one back door, totally two doors; with anti-theft three point lock for outdoor cabinet (support padlock)

    (4) Material: galvanized steel; double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

    2Air Conditioner2Set

    Power Supply: DC48V

    Cooling Capacity:500W

    Model: SAD105

    3Power Distribution Unit1Set

    Grade B Lightning Proof

    AC Input: 63A/2P *1;

    AC Output: 16A/1P*4;

    DC Output: 16A/1P*4.

    Height: 4U

    4Environment Monitoring System1Set

    1× environment monitoring unit, with TCP/IP communication port;

    1× water sensor;

    1× smoke sensor;

    1× temperature and humidity sensor;

    2× door sensor

    5LED Lamp1PcDC48V
    6Package1SetWooden Case

    2. Application Scope


    The Outdoor Telecom Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

    3. Cabinet Introduction

    3.1 Cabinet Material


    The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF, heat insulation coefficient: 0.035W/m·K. The cabinet is assembled type.

    3.2 Cabinet Structure


    The cabinet includes 19” equipment installation rack. The cabinet includes two air conditioners, one installed on front door and another installed on back door.

    3.3 Cabinet Door and Lock


    The cabinet includes one front door and one back door. The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.


    4. Features


    4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.

    4.2 The cabinet cooling uses air conditioner.

    4.3 Including -48VDC illumination LED lamp.

    4.4 The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc.

    4.5 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are cable inlets separately for power cable, signal cable and optical cable.

    4.6 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.

    4.7 The cabinet includes 19” standard installation rack.


    5. Technical Specs

    • Applicable environment conditions:

    Operating temperature: -40°C ~ + 55°C

    Storage temperature: -50°C ~ + 70°C

    Transport temperature: -50°C ~ + 70°C

    Relative humidity (RH): 5%~99%

    Air pressure: 62kPa ~ 101kPa (similar to 0m ~ 5000m altitude)

    • Material: good quality galvanized steel
    • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
    • Cabinet load bearing: ≥600kg
    • Ingress protection: IP65
    • Flame retardance: comply with GB5169.7 test A
    • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
    • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
    • Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

    Dimension Diagram


    Cabinet External Dimension (W×D×H): 1000×1000×1800mm.


    6. Components Installation

    6.1 LED lamp, LED lamp sensor, smoke sensor, door sensor and temperature & humidity sensor are installed at the top of the cabinet.



    6.2 Water sensor is installed at the bottom of the cabinet.



    6.3 PDU and environment monitoring unit are installed on 19” rack.



    6.4 The cabinet includes totally two air conditioners, one air conditioner installed on front door and the other installed on back door.



    6.5 The cabinet includes rubber base plate, for installation on transport telecom tower trailer.



    7. Cable Inlet


    Feeder cable and other external cables all use bottom wiring method.


    8. Grounding Protection


    • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
    • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
    • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

    9. Theft Proof Design

    9.1 Door lock theft proof design

    • Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.


    • Three point lock


    9.2 Connection and Fastening


    • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
    • Door hinges use inner hinge mode.

    9.3 Appearance and Surface Treatment


    Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.


    10. Cabinet Installation


    10.1 Position of installation holes at cabinet base are as follows:



    Diagram 1


    10.2 Users prefabricate concrete base.

    10.3 Pre-embed 4pcs M10×120 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1. Bolt exposed height is 40mm. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench.

    10.4 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts.


    11. PDU Principle Diagram


    12. Air Conditioner

    (1) Compressor Air Conditioner.
    Model: SAD105.
    Power Supply: DC48V.
    Cooling Capacity: 500W.
    Quantity: 2 pcs air conditioners for each cabinet, one installed on front door and the other installed on rear door.


    (2) Working Principle: the cabinet includes auto switching controller for the two air conditioners. Air conditioner 1 is main air conditioner, and air conditioner 2 is backup air conditioner. Air conditioner 1 will keep working if there is no failure and alarm; only in case air conditioner 1 send failure alarm, air conditioner 2 will start to work, and air conditioner 1 will stop working.


    13. Packing and Shipping



    Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc.

    Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


    14. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality IP65 Outdoor Telecom Cabinet for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0